ONEIC.US
8975590000

点击放大查看

对参数有疑问?问 AI 助手

Business

Standard Package1

Compliance

RoHSLead free / RoHS CompliantSafety CategoryDEMKO07ATEX143595X
Declaration of ConformityDeclaration of Conformity

Electrical

Currentmax. 100 µAFrequency50...60 Hz
IndicatorLED ON: OK; FLASHING: signal out of range;LED OFF: ErrorRange deg/s0.5 mm²
Load Current≤ 600 ΩOutput SignalApprox. 24 mA
Current - Output4...20 mA (current loop)Number of Inputs1
Number of Outputs1Current - Input Bias0...1 A AC/ 0...5 A AC/ 0...10 A AC

Mechanical

Depth112.4 mmWidth22.5 mm
Length72 mmWeight101 g
Connector TypeScrew connectionDepth (Inches)4.425 inch
Width (Inches)0.886 inchLength (Inches)2.835 inch
Package Quantityinstruction sheet.pdf

Product Info

TypeWAS1 CMA LP 1/5/10A EXSeries*
GTIN (EAN)4050118023640DescriptionCross-connectors for power supplies and markers – refer to Accessories
SpecificationsMonitoring component for AC currents up to 10A with 4...20 mAloop feed and electrical isolationCurrent monitoring component in 22.5 mm width for recording 50/ 60 HzAC currents 0...1 A / 0...5 A / 0...10 A. Input range can be selected using DIP switches.Power is fed to the component via the 4...20 mA current loop on the output side.The input and output circuits have 6 kV of electrical isolation.Approved for ATEX Zone2 and UL C1 D2 applications.Add-on housing for TS35 rail mountingDimensions: L/W/H 72/ 22.5/ 92.4 mmScrew connection / Nominal cross-section 2.5 mm2Protection degree: IP 20   Input                         0...1 A / 0...5 A / 0...10 A AC switchable                                      50 / 60 HzVoltage of measuring circuit 250 V ACOutput                                             4...20 mA current loopLoad resistance            < 600 Ohm Strom>1 kOhm / voltageTransmission error               < 0,5% v. E. Temperature coefficient 200 ppm / KStep response time typ. 700 msAuxiliary power                                     via output-side current loopAmbient temperature range 0 °C...+50 °C Secure isolation                   EN 50178, 2-way isolation up to 6 kVTest voltage                               4 kV input against outputRated voltage                                         300 V AC/DC at overvoltage category III and pollution degree 2Approvals cULus, cULusEX C1D2, ATEX Zone 2Type                                                            WAS1 CMA LP 1/5/10A EXFirmware VersionWAVESERIES, Current monitoring, 0...1 A AC/ 0...5 A AC/ 0...10 A AC, 1, 1, Screw connection

Environmental

Ingress Protection27-21-01-07Operating Temperature0 °C...50 °C