ONEIC.US
8705630000

点击放大查看

对参数有疑问?问 AI 助手

Business

Standard Package1

Compliance

RoHSLead free / RoHS CompliantStandardsDIN EN 50178
IEC 61000-4-2EN 55011, EN 61000-6, EN 61326Standard Number30-21-18-01
Declaration of ConformityDeclaration of Conformity

Electrical

Accuracy< 0.3 % of set rangeFrequency27-37-18-01
IndicatorGreen LEDIsolation3-way isolator
Hysteresis5% of final valueRange deg/s0.5 mm²
Response Time< 300 msSettling TimeDIP switches: ON = 1,2,4 / OFF = 3
Current - Test3 AVoltage Rating600 V
Number of Inputs5Voltage - Supplyfrom the measuring circuit
Voltage - Breakdown4 kVeff / 1 min.Voltage - Input (Min)250 V AC
Voltage - Switching AC250 VImpulse Discharge Current (8/20us)6 kV

Mechanical

Depth112.4 mmWidth22.5 mm
Length96.5 mmWeight120.6 g
Connector TypeScrew connectionDepth (Inches)4.425 inch
Mounting RailsTS 35Width (Inches)0.886 inch
Length (Inches)3.799 inchPackage Quantityinstruction sheet.pdf

Product Info

TypeWAS2 VMR 3phSeries*
ETIM 6*0EC002046Function1-/3-phase monitoring
GTIN (EAN)4032248377060DescriptionMarkers – refer to Accessories.
ConfigurationDIP switch, Potentiometer, Alarm status reset via reset input or buttonSpecificationsLimit-value monitoring component   for 1- /3- phase AC and DC voltageswith relay output and electrical isolationlimit-value monitoring component in 22.5 mm width for recording 1-phaseAC/DC voltages 200...400 V or 3-phase AC- voltages of 80...250 V.A relay contact (CO) with a switching capacity of 750 VAis available on the output side.Input ranges, high/low trip alarm, monitored voltage window andswitching behaviour (for working and quiescent currents) can be configured using DIP switchesSwitching threshold can be adjusted with front-side potentiometerPower is supplied via the measured circuit. The I/O circuits have 6 kV of electrical isolation.Add-on housing for TS35 rail mountingDimensions: L/W/H 96.5/ 17.5/ 112.4 mmScrew connection / Nominal cross-section 2.5 mm2Protection degree: IP 20   Input                         3 phases 80 V...250 V AC                                      1 phase 200...400 V AC/DC                                      switchableVoltage of measuring circuit max 400 VOutput                                             Relay / COSwitching current 3 ASwitching voltage 6... 250 V AC / 6...60 V DCSwitching threshold via potentiometerVoltage window        small 10 % AC / 20 % DC // large 12 % AC / 25 % DC adjustableHysteresis 5 % AC / 6 % DC of inputTemperature coefficient   < 300 ppm KStep response time        < 300 msAmbient temperature range 0 °C...+50 °C Secure isolation                   EN 50178, 2-way isolation up to 6 kVTest voltage               4 kVeff / 1 min. Input / OutputRated voltage                                          600 V AC/DC at overvoltage category III and pollution degree 2Approvals cULusType                                                             WA5 VMR 3ph
Firmware VersionWAVESERIES, Voltage monitoring, 5, 250 V, Screw connectionOther SpecificationsIII

Environmental

DistanceOutput circuit: 1.8 mm; input circuit, output circuit 1/output circuit 2: 3 mm; input/output: 5.5 mmET (Volt-Time)EC001438
Operational Life493 YearsIngress Protection2
Operating Temperature0 °C...50 °CTemperature Coefficient≤ 300 ppm/K