Signal Converter/Disconnector 12-Pin CONDITIONER SIGNAL DINRAIL MNT
Category
对参数有疑问?问 AI 助手

Business

Other NamesWAZ5 VCC 0-10V/4-20MStandard PackageBulk

Compliance

RoHSLead free / RoHS CompliantStandardsDIN EN 50178, DIN EN 61000-4-2
IEC Standard27-21-01-20IEC 61000-4-2EN 55011, EN 61000-6
Standard Number31-12-10-07Declaration of ConformityDeclaration of Conformity

Electrical

Accuracy0.2 %Frequency27-21-01-20
Isolation3-way isolatorRange deg/s0.5 mm²
Load Current≤ 600 ΩResponse Time≤ 45 ms
Voltage Rating0...10 VCurrent - Carry≤ 2 A
Current - Output4...20 mANumber of Inputs1
Voltage - Supply24 V DC ± 25 %Number of Outputs1
Resistance - Inputtyp. 100 kΩVoltage - Breakdown2 kVeff / 5 s
Frequency - Output 310 HzRatio - Input:Output0...10 V/ 4...20 mA
Voltage - Input (Min)4 kVeff / 1 min.Power - Average Forward< 1.5 W @ IOUT = 20 mA
Voltage - Output Supply2 kVeff / 5 sImpulse Discharge Current (8/20us)4 kV

Mechanical

Depth112.4 mmWidth17.5 mm
Length92.4 mmWeight101.1 g
Connector TypeTension clamp connectionDepth (Inches)4.425 inch
Mounting RailsTS 35Width (Inches)0.689 inch
Length (Inches)3.638 inchPackage Quantityinstruction sheet.pdf
Stripping Length7 mm

Product Info

TypeWAZ5 VCC 0-10V/4-20MASeries*
ETIM 6*0EC002653GTIN (EAN)4032248180684
DescriptionCross-connectors for power supplies and markers: refer to accessoriesConfigurationnone
SpecificationsStandard signal isolating converter1-channel signal isolating converter in 17.5 mm width, with external power supply,to transmit and isolate analogue DC current signals from 0 to 10 VAdd-on housing for TS35 rail mountingDimensions: L/W/H 92.4/ 17.5/ 112.4 mmTension-clamp connection / Nominal cross-section 1.5 mm2Protection degree: IP 20   Input                         0...10 VOutput                                             4...20 mATransmission error             < 0,2% v. E. Limit frequency 10 HzAuxiliary power                                     24 VDC +/- 25 %Power loss approx. 1.3 WAmbient temperature range 0 °C...+55 °CSecure isolation                   EN 50178, 3-way isolation up to 4 kV AC/DC of all circuits against each otherTest voltage                             4 kV input against output against auxiliary powerRated voltage                                         300 V AC/DC at overvoltage category III and pollution degree 2Approvals cULusType                                                             WAZ5 VCC 0-10/4-20MAEngineering DataEPLAN
Firmware VersionSignal converter/insulator, Tension clamp connectionOther SpecificationsIII

Environmental

Distance≥ 3 mmET (Volt-Time)EC001774
Ingress Protection2Operating Temperature0 to 55 °C
Temperature Coefficient± 250 ppm/K

Documents & Media

PDF Document