ONEIC.US
8523410000

点击放大查看

8523410000

Manufacturer
Description
Current Monitoring 9-Pin CONDITIONER SGNL DINRAIL MNT AC
Category
对参数有疑问?问 AI 助手

Business

Other NamesWAZ1CACStandard PackageBulk

Compliance

RoHSLead free / RoHS CompliantDeclaration of ConformityDeclaration of Conformity

Electrical

Currentmax. 100 µAFrequency50...60 Hz
IndicatorLED ON: OK; FLASHING: signal out of range;LED OFF: ErrorRange deg/s0.5 mm²
Load Current≤ 600 ΩOutput SignalApprox. 13 V or 24 mA
Voltage - Load≥ 1 kΩCurrent - Output0(4)...20 mA
Number of Inputs1Number of Outputs1
Current - Input Bias0...1 A AC/ 0...5 A AC/ 0...10 A ACVoltage - Input (Min)0...10 V
Voltage - Input Offset (Max)max. 0.05 V

Mechanical

Depth92.4 mmWidth22.5 mm
Length72 mmWeight108 g
Connector TypeTension clamp connectionDepth (Inches)3.638 inch
Width (Inches)0.886 inchLength (Inches)2.835 inch
Package Quantityinstruction sheet.pdf

Product Info

TypeWAZ1 CMA 1/5/10A acSeries*
ETIM 6*0EC002048GTIN (EAN)4032248173341
DescriptionCross-connectors for power supplies and markers – refer to AccessoriesSpecificationsMonitoring component for AC currents up to 10A with standard signal output and electrical isolationCurrent monitoring component in 22.5 mm width for recording 50/ 60 Hz AC currents 0...1 A / 0...5 A / 0...10 A. Standardised analogue current/voltage signals are available on the output side. Input and output ranges can be adjusted via DIP switches. The 24 VDC power is supplied over the output circuit. The input and outputs are designed with 6 kV of electrical isolation. Add-on housing for TS35 rail mounting Dimensions: L/W/H 72/ 22.5/ 92.4 mm Tension-clamp connection / Nominal cross-section 1.5 mm2Protection degree: IP 20   Input                         0...1 A / 0...5 A / 0...10 A AC switchable                                       50 / 60 Hz Voltage of measuring circuit 250 V AC Output                                             0(4)...20 mA / 0...10 V Load resistance            < 600 Ohm Strom >1 kOhm / voltageTransmission error           < 0,5% v. E.  Temperature coefficient 200 ppm / K Step response time typ. 700 msAuxiliary power                                     24 VDC +/- 10 % via output circuit Ambient temperature range 0 °C...+50 °C Secure isolation                   EN 50178, 2-way isolation up to 6 kVTest voltage                               4 kV input against outputRated voltage                                         300 V AC/DC at overvoltage category III and pollution degree 2 Approvals cULus Type                                                             WAZ1 CMA 1/5/10A ac
Firmware VersionWAVESERIES, Current monitoring, 0...1 A AC/ 0...5 A AC/ 0...10 A AC, 1, 1, Tension clamp connection

Environmental

ET (Volt-Time)EC002048Operational Life533 Years
Ingress Protection27-37-18-02Operating Temperature0 to 50 °C

Documents & Media

PDF Document