点击放大查看
8523410000
| Manufacturer | |
| Description | Current Monitoring 9-Pin CONDITIONER SGNL DINRAIL MNT AC |
| Category |
对参数有疑问?问 AI 助手
Business
| Other Names | WAZ1CAC | Standard Package | Bulk |
Compliance
| RoHS | Lead free / RoHS Compliant | Declaration of Conformity | Declaration of Conformity |
Electrical
| Current | max. 100 µA | Frequency | 50...60 Hz |
| Indicator | LED ON: OK; FLASHING: signal out of range;LED OFF: Error | Range deg/s | 0.5 mm² |
| Load Current | ≤ 600 Ω | Output Signal | Approx. 13 V or 24 mA |
| Voltage - Load | ≥ 1 kΩ | Current - Output | 0(4)...20 mA |
| Number of Inputs | 1 | Number of Outputs | 1 |
| Current - Input Bias | 0...1 A AC/ 0...5 A AC/ 0...10 A AC | Voltage - Input (Min) | 0...10 V |
| Voltage - Input Offset (Max) | max. 0.05 V | ||
Mechanical
| Depth | 92.4 mm | Width | 22.5 mm |
| Length | 72 mm | Weight | 108 g |
| Connector Type | Tension clamp connection | Depth (Inches) | 3.638 inch |
| Width (Inches) | 0.886 inch | Length (Inches) | 2.835 inch |
| Package Quantity | instruction sheet.pdf | ||
Product Info
| Type | WAZ1 CMA 1/5/10A ac | Series | * |
| ETIM 6*0 | EC002048 | GTIN (EAN) | 4032248173341 |
| Description | Cross-connectors for power supplies and markers – refer to Accessories | Specifications | Monitoring component for AC currents up to 10A with standard signal output and electrical isolationCurrent monitoring component in 22.5 mm width for recording 50/ 60 Hz AC currents 0...1 A / 0...5 A / 0...10 A. Standardised analogue current/voltage signals are available on the output side. Input and output ranges can be adjusted via DIP switches. The 24 VDC power is supplied over the output circuit. The input and outputs are designed with 6 kV of electrical isolation. Add-on housing for TS35 rail mounting Dimensions: L/W/H 72/ 22.5/ 92.4 mm Tension-clamp connection / Nominal cross-section 1.5 mm2Protection degree: IP 20 Input 0...1 A / 0...5 A / 0...10 A AC switchable 50 / 60 Hz Voltage of measuring circuit 250 V AC Output 0(4)...20 mA / 0...10 V Load resistance < 600 Ohm Strom >1 kOhm / voltageTransmission error < 0,5% v. E. Temperature coefficient 200 ppm / K Step response time typ. 700 msAuxiliary power 24 VDC +/- 10 % via output circuit Ambient temperature range 0 °C...+50 °C Secure isolation EN 50178, 2-way isolation up to 6 kVTest voltage 4 kV input against outputRated voltage 300 V AC/DC at overvoltage category III and pollution degree 2 Approvals cULus Type WAZ1 CMA 1/5/10A ac |
| Firmware Version | WAVESERIES, Current monitoring, 0...1 A AC/ 0...5 A AC/ 0...10 A AC, 1, 1, Tension clamp connection | ||
Environmental
| ET (Volt-Time) | EC002048 | Operational Life | 533 Years |
| Ingress Protection | 27-37-18-02 | Operating Temperature | 0 to 50 °C |
Documents & Media
PDF Document