点击放大查看
8523400000
| Manufacturer | |
| Description | Current Monitoring 9-Pin CONDITIONER SIGNAL RAIL MNT |
| Category |
对参数有疑问?问 AI 助手
Business
| Other Names | WAS1CMA1/5/10AAC | Standard Package | Bulk |
Compliance
| RoHS | Lead free / RoHS Compliant | Standard Number | 30-21-18-01 |
| Declaration of Conformity | Declaration of Conformity | ||
Electrical
| Current | max. 100 µA | Frequency | 50...60 Hz |
| Indicator | LED ON: OK; FLASHING: signal out of range;LED OFF: Error | Range deg/s | 0.5 mm² |
| Load Current | ≤ 600 Ω | Output Signal | Approx. 13 V or 24 mA |
| Voltage - Load | ≥ 1 kΩ | Current - Output | 0(4)...20 mA |
| Number of Inputs | 1 | Number of Outputs | 1 |
| Current - Input Bias | 0...1 A AC/ 0...5 A AC/ 0...10 A AC | Voltage - Input (Min) | 0...10 V |
| Voltage - Input Offset (Max) | max. 0.05 V | ||
Mechanical
| Depth | 92.4 mm | Width | 22.5 mm |
| Length | 72 mm | Weight | 76.9 g |
| Termination | Screw connection | Connector Type | Screw connection |
| Depth (Inches) | 3.638 inch | Width (Inches) | 0.886 inch |
| Length (Inches) | 2.835 inch | Package Quantity | instruction sheet.pdf |
Product Info
| Type | WAS1 CMA 1/5/10A ac | Series | * |
| ETIM 6*0 | EC002048 | GTIN (EAN) | 4032248151691 |
| Description | Cross-connectors for power supplies and markers – refer to Accessories | Product Type | 2044850000 |
| Specifications | Monitoring component for AC currents up to 10A with standard signal outputand electrical isolationCurrent monitoring component in 22.5 mm width for recording 50/ 60 Hz AC currents0...1 A / 0...5 A / 0...10 A. Standardised analogue current/voltage signalsare available on the output side. Input and output ranges can be adjusted via DIP switches.The 24 VDC power is supplied over the output circuit.The input and outputs are designed with 6 kV of electrical isolation.Add-on housing for TS35 rail mountingDimensions: L/W/H 72/ 22.5/ 92.4 mmScrew connection / Nominal cross-section 2.5 mm2Protection degree: IP 20 Input 0...1 A / 0...5 A / 0...10 A AC switchable 50 / 60 HzVoltage of measuring circuit 250 V ACOutput 0(4)...20 mA / 0...10 VLoad resistance < 600 Ohm Strom>1 kOhm / voltageTransmission error < 0,5% v. E. Temperature coefficient 200 ppm / KStep response time typ. 700 msAuxiliary power 24 VDC +/- 10 % via output circuitAmbient temperature range 0 °C...+50 °C Secure isolation EN 50178, 2-way isolation up to 6 kVTest voltage 4 kV input against outputRated voltage 300 V AC/DC at overvoltage category III and pollution degree 2Approvals cULusType WAS1 CMA 1/5/10A ac | Firmware Version | WAVESERIES, Current monitoring, 0...1 A AC/ 0...5 A AC/ 0...10 A AC, 1, 1, Screw connection |
| Other Specifications | This article will no longer be available in the future. | ||
Environmental
| ET (Volt-Time) | EC001440 | Operational Life | 533 Years |
| Ingress Protection | 27-21-09-02 | Operating Temperature | 0 to 50 °C |
Documents & Media
PDF Document