ONEIC.US
对参数有疑问?问 AI 助手

Business

Standard Package1

Compliance

RoHSConformStandardsIEC 61010-1
IEC Standard27-21-01-20IEC 61000-4-2IEC 61326-1, NE 21
Safety CategoryKEMA10ATEX0183XApproval Agency MarkingIECEXKEM10.0090X
Declaration of ConformityDeclaration of Conformity

Electrical

SensorCurrent sourceAccuracy< 0.05 % of measuring range
Frequency100 HzIsolation2-way isolator
Range deg/s0.5 mm²Current - ULE337701.pdf
Load Current≤ 600 Ω (channel 1 +2), @ max 23mAResponse Time≤ 5 ms
Voltage Rating300 VeffCurrent - Output4...20 mA
Voltage - SupplyOutput loop poweredNumber of Outputs2
Voltage - Breakdown2.5 kVeff / 1 min.Current - Input Bias4...20 mA
Frequency - Output 3100 HzVoltage - Input (Min)Typical 2.5 V
No Load Power Consumption30 mW per channel

Mechanical

Depth114.3 mmWidth6.1 mm
Height112.5 mmWeight96 g
Wire Gauge2.5 mm²Connector TypeScrew connection
Depth (Inches)4.5 inchMounting RailsTS 35
Width (Inches)0.24 inchHeight (Inches)4.429 inch
Package Quantityinstruction sheet.pdf

Product Info

TypeACT20M-2CI-2CO-OLP-SSeries*
ETIM 6*0EC002653GTIN (EAN)4032248969999
DescriptionDIN mounting rail, see AccessoriesProduct TypeThe passive isolator ACT20M-CI-CO-OLP-S isolates standard analogue current signals. An analogue input current signal is linearly converted into an analogue output current signal and galvanically isolated. Power is supplied through the output measurement circuit (output loop-powered). The passive isolator ACT20M-2CI-2CO-OLP-S offers the same functionality, but has two galvanically isolated channels..
ConfigurationnoneSpecificationsStandard signal isolating amplifier2-channel signal isolating amplifier in 6.1 mm width output-loop powered,for transmitting and isolating analogue DC current signals 0/4...20 mA.Add-on housing for TS35 rail mountingDimensions: L/W/H 114.3/ 6.1/ 112.5 mmScrew connection / Nominal cross-section 2.5 mm2Protection degree: IP 20   Input                         0/4...20 mAOutput                                             0/4...20 mALoad resistance             < 600 OhmTransmission error             < 0,1 % v. E. Limit frequency 100 HzAuxiliary power                                     0/4...20 mA output current loop Power loss approx. 1.2 W Ambient temperature range -25 °C...+70 °C Isolation                                EN 61010-1, 2-way isolation up to 2.5 kV AC/DCTest voltage                               2.5 kV input against output against auxiliary powerRated voltage                                         300 V AC/DC at overvoltage category II and pollution degree 2Approvals cULus, FM Div2, ATEX Zone2, DNV, GLType                                                             ACT20M-2CI-2CO-OLP-S
Engineering DataEPLANFirmware VersionSignal converter/insulator, dual channel, Output current loop powered, 2-way isolator, Output loop powered
Other SpecificationsTypical 2.5 VDescriptive Text Technical DataPower supply optionally over the DIN mounting rail CH20M

Environmental

Temperature-25 °C...+70 °CET (Volt-Time)EC002479
Humidity Range40 °C / 93 % rel. humidity, no condensationIngress Protection2
Operating Temperature-25 °C...70 °CTemperature Coefficient≤± 0.07 µA x (Δ °C x V supply) @ Tamb < 25 °C, ≤±0.02 µA x (Δ °C x V supply) @ Tamb > 25 °C