| Manufacturer | |
| Description | 12BAR 2 POLE POWER PRESS SW Schneider Electric component XMPR12B2433: pressure sensor XMP - 12 bar - 4xG 1/4 female - 2 NC - ON/OFF knob control |
| Category |
对参数有疑问?问 AI 助手
Compliance
| Standards | CEEN/IEC 60947-4-1 | Protection | Class I conforming to IEC 60536 |
Electrical
| Accuracy | < 3.5 % | Resistance | <= 25 MOhm conforming to IEC 60255-7 category 3<= 25 MOhm conforming to NF C 93-050 method A |
| Sensor Type | Electromechanical pressure sensor | Voltage Rating | 500 V conforming to EN/IEC 60947-1 |
| Circuit Pattern | Power circuit | Range of Values | 0.3...10.3 bar |
| Frequency - Operating | 10 cyc/mn | Switch Function/Rating | Regulation between 2 thresholds |
| Connector - Voltage Input | (1-2)NC(3-4)NC | Current - Dark (Id) (Max) | 1 bar |
| Voltage - Breakdown (V(BR)GSS) | 6 kV conforming to EN/IEC 60947-1 | Current - LED Trigger (Ift) (Max) | 1.7 bar |
| Dynamic Range, ADCs / DACs (db) Typ | 8.4 bar | ||
Mechanical
| Weight | 0.45 kg | Actuator Type | Diaphragm |
| Cable End Type | 4 x G 1/4 (female) conforming to ISO 228 | Connector Type | Screw-clamp terminals, clamping capacity: minimum : 2 x 4 mm ² |
| Depth - Overall | 98 mm | Plug Wire Entry | 2 entries tapped for Pg 13.5 cable gland conforming to NF C 68-300 |
| Width - Overall | 57 mm | Adjustment Range | 1.3...12 bar |
| Contact Material | 2 NC snap action | Height - Overall | 138 mm |
| Size / Dimension | 12 bar | Terminal Block Type | 4 terminals |
| Material - Insulation | Canvas covered nitrileChromated zinc alloy | Exterior Housing Material | PA impregnated with fibreglass |
Product Info
| Type | Adjustable differential | Display Style | Without |
| Control Method | ON/OFF knob | Electrical Life | 1000000 cycles (1.5 kW, operating rate: 10 cyc/mn, load factor: 0.4, 400 V AC 3 phases)500000 cycles (3 kW, operating rate: 10 cyc/mn, load factor: 0.4, 400 V AC 3 phases)600000 cycles (1.5 kW, operating rate: 10 cyc/mn, load factor: 0.4, 230 V AC 3 phases)700000 cycles (2.2 kW, operating rate: 10 cyc/mn, load factor: 0.4, 400 V AC 3 phases) |
| Measuring Range | OsiSense XM | Number of Units | 1 |
| Operating Position | Any position | Other Specifications | XMP |
Environmental
| Fluid Type | Air (0...70 °C)Fresh water (0...70 °C)Sea water (0...70 °C) | Pressure Type | Straight valve olive connection |
| Burst Pressure | 30 bar | Mechanical Life | 1000000 cycles |
| Shock Resistance | 50 gn conforming to IEC 60068-2-27 | Storage Interface | -40...70 °C |
| Ingress Protection | IP65 EN/IEC 60529 | Vibration Resistance | 3 gn (f = 10...500 Hz) conforming to IEC 60068-2-6 |
| Operating Temperature | -25...70 °C | ||