ONEIC.US
XCSTE7312

点击放大查看

XCSTE7312

Manufacturer
Description
Solenoid 2 insulated switch,2NC+1NC Keylock Switches SAFETY INTERLOCK 240VAC 5A T-XCS Schneider Electric component XCSTE7312: plastic safety switch XCSTE - 2 NC - slow break - 1entry tapped M16 x 1.5 - 24 V
Category
对参数有疑问?问 AI 助手

Business

Lead Time14 DaysSubcategorySwitch Safety Interlock

Compliance

RoHSNot ApplicableStandardsCSA C22-2 No 14EN 1088/ISO 14119EN/IEC 60204-1EN/IEC 60947-5-1EN/ISO 12100UL 508
ProtectionClass II conforming to EN/IEC 60536CertificationCSAUL
Safety CategoryB10d = 5000000 (value given for a life time of 20 years limited by mechanical or contact wear)

Electrical

Speed0.5 m/sVoltage Rating250V
Number of PolesDPMaximum AC Volts240V
Voltage - Supply50/60 HzPower - Peak PulseSolenoid Energised to Unlock
Current Rating (Max)0.55 A at 125 V utilisation category DC-13, Q300 conforming to EN/IEC 60947-5-10.27 A at 250 V utilisation category DC-13, Q300 conforming to EN/IEC 60947-5-13 A at 120 V utilisation category AC-15, B300 conforming to EN/IEC 60947-5-11.5 A at 240 V utilisation category AC-15, B300 conforming to EN/IEC 60947-5-1Frequency - Operating10 cyc/mn for maximum durability
Power - Average Forward10 VANo Load Power Consumption10 VA
Voltage - Breakdown (V(BR)GSS)6 kV conforming to EN/IEC 60947-5-1Current - Short Circuit Rating (SCCR)10 A cartridge fuse type gG (gl)

Mechanical

Depth110mmWidth33mm
Length93.5mmWeight0.36 kg
MaterialPlasticHead StyleKey operated turret head
InsulationDouble insulatedBody MaterialPA (polyamide)
Opening Force15 NConnector TypeTerminal, 1 x 0.5...2 x 1.5 mm ² with or without cable end
Contact TimingSlow-break, simultaneousMaterial - TipPA (polyamide)
Actuation Force500 NDepth - Overall33 mm
Locking FeatureWith interlocking, locking by solenoidPlug Wire Entry1 entry tapped M16 x 1.5
Width - Overall110 mmContact Material2 NC
Height - Overall94 mmHousing MaterialPlastic
Positive OpeningWith NC contactMaterial - MagnetLocking on de-energisation and unlocking on energisation of solenoid
Supplier Device PackageXCSTEOutside Pipe Diameter (Max)7...10 mm
Operating Force - Mid Compression0.01 m/s

Product Info

DesignRectangularComposition1 NC (slow-break)
Form Factor1Product TypeSafety switch
Measuring RangePreventa Safety detectionConduit Hub SizePG11
Industry Aliases3389110825114, XCSTE7312Normal State Configuration2NC

Environmental

Seal RatingIP67Mechanical Life1000000 cycles
Shock Resistance10 gn for 11 ms conforming to IEC 60068-2-27Storage Interface-40...70 °C
Ingress ProtectionIP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1Protective TreatmentTC
Vibration Resistance5 gn (f = 10...500 Hz) conforming to IEC 60068-2-6Operating Temperature-25...60 °C
Thermal Current (Ith)6 A