ONEIC.US
XCSA712

点击放大查看

XCSA712

Manufacturer
Description
Keylock Switches SAFETY INTERLOCK 300VAC 10A T-XCS Schneider Electric component XCSA712: metal safety switch XCSA - 2 NC + 1 NO - slow break - 1 entry tapped M20 x 1.5
Category
对参数有疑问?问 AI 助手

Business

Lead Time14 DaysSubcategorySwitch Safety Interlock

Compliance

StandardsCSA C22-2 No 14EN 1088/ISO 14119EN/IEC 60204-1EN/IEC 60947-5-1EN/ISO 12100UL 508ProtectionClass I conforming to EN/IEC 60536
CertificationCSAULSafety CategoryB10d = 5000000 (value given for a life time of 20 years limited by mechanical or contact wear)

Electrical

Speed0.5 m/sVoltage Rating500 V conforming to EN/IEC 60947-1300 V conforming to CSA C22-2 No 14300 V conforming to UL 508
Number of Poles3Current Rating (Max)6 A at 120 V utilisation category AC-15, A300 conforming to EN/IEC 60947-5-13 A at 240 V utilisation category AC-15, A300 conforming to EN/IEC 60947-5-10.55 A at 125 V utilisation category DC-13, Q300 conforming to EN/IEC 60947-5-10.27 A at 250 V utilisation category DC-13, Q300 conforming to EN/IEC 60947-5-1
Frequency - Operating10 cyc/mn for maximum durabilityVoltage - Open Circuit24/48 V
Voltage - Breakdown (V(BR)GSS)6 kV conforming to EN/IEC 60947-5-1Current - Short Circuit Rating (SCCR)10 A cartridge fuse type gG (gl)

Mechanical

Weight0.44 kgMaterialMetal
Head StyleKey operated turret headBody MaterialZamak
Connector TypeTerminal, 1 x 0.5...2 x 1.5 mm ² with or without cable endContact TimingSlow-break, break before make
Material - TipZamakActuation Force>= 20 N
Depth - Overall44 mmLocking FeatureWithout locking of actuator
Plug Wire Entry1 entry tapped M20 x 1.5Width - Overall40 mm
Contact Material2 NC + 1 NOHeight - Overall114 mm
Positive OpeningWith NC contactSupplier Device PackageXCSA
Outside Pipe Diameter (Max)7...13 mmOperating Force - Mid Compression0.01 m/s

Product Info

DesignIndustrialCircuit TypeAC/DC
Product TypeSafety switchMeasuring RangePreventa Safety detection
Industry Aliases785901443056, XCSA712Other Specifications1 LED orange (on opening of NC contacts)

Environmental

Mechanical Life>= 1000000 cyclesShock Resistance10 gn for 11 ms conforming to IEC 60068-2-27
Storage Interface-40...70 °CIngress ProtectionIP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1
Protective TreatmentTCVibration Resistance5 gn (f = 10...500 Hz) conforming to IEC 60068-2-6
Operating Temperature-25...70 °CThermal Current (Ith)10 A