ONEIC.US
LUCL1XES

点击放大查看

LUCL1XES

Manufacturer
Description
Magnetic Control Unit,48-72V,1.4A Schneider Electric component LUCL1XES: magnetic control unit LUCL 0.35...1.4 A - 48â
Category
对参数有疑问?问 AI 助手

Compliance

StandardsCSA C22-2 No 14 type EEN 60947-6-2IEC 60947-6-2UL 508 type E with phase barrierCertificationCE

Electrical

ResetAutomatic reset - setting: setting rangeManual - setting: factory settingManual - setting: setting rangeRemote reset - setting: setting rangeCircuit400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1
Load Type3-phase motor - cooling: self-cooled - setting factory settingSingle-phase motorReset Time120 s - reset manual - setting factory setting1...1000 s - reset manual or automatic reset - setting settable
Trip Range14.2 x Ir +/- 20 %Power - Rated0.25 kW
Voltage - I/O70 % 500 ms conforming to IEC 61000-4-11Power - Output0.25 kW at < 400...415 V AC 50/60 Hz
Voltage Rating600 V conforming to CSA 22-2 No 14600 V conforming to UL 508690 V conforming to IEC 60947-1Current - Output280 mA at 48...72 V AC I maximum while closing with LUB12280 mA at 48...72 V AC I maximum while closing with LUB32280 mA at 48...72 V DC I maximum while closing with LUB12280 mA at 48...72 V DC I maximum while closing with LUB3235 mA at 48...72 V AC I rms sealed with LUB1235 mA at 48...72 V DC I rms sealed with LUB1245 mA at 48...72 V AC I rms sealed with LUB3245 mA at 48...72 V DC I rms sealed with LUB32
Voltage - Supply29 V for AC circuit 48...72 V drop-out29 V for DC circuit 48...72 V drop-out38.5...72 V for AC circuit 48...72 V in operation38.5...93 V for DC circuit 48...72 V in operationPower Dissipation (Max)2 W for control circuit with LUB123 W for control circuit with LUB32
Voltage - Breakdown (V(BR)GSS)6 kV conforming to IEC 60947-6-2Impedance - Unbalanced/Balanced10 V/m 3 conforming to IEC 61000-4-3
Resistance - Wiper (Ohms) (Typ)8 kV level 3 in open air conforming to IEC 61000-4-28 kV level 4 on contact conforming to IEC 61000-4-2ESR (Equivalent Series Resistance)2 kV class 3 serial link conforming to IEC 61000-4-44 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
Common Mode Transient Immunity (Min)3 ms

Mechanical

Weight0.135 kgMounting TypePlug-in
Dielectric Diameter10 V conforming to IEC 61000-4-6

Product Info

TypeMagnetic Control UnitUsageAC-41AC-43AC-44
FunctionManual resetShort-circuit protectionLanguageEnglish - setting factory settingEnglish, French, German, Italian, Spanish - setting settable
Product TypeMagnetic control unitCompatibilityASILUFC5ASILUFC51LUFC00LULC031LULC033LULC07LULC08LULC09LULC15
Display FormatAverage current - setting factory settingAverage current - setting settableCause of last 5 faults - setting settableCurrent in phase - setting settableEarth leakage current - setting settablePhase imbalance - setting settableThermal state of motor - setting settableMeasuring RangeTeSys U
Device Short NameLUCLControl/Display Type48 V ac, 48 → 72 V dc
Other Specifications0.35 → 1.4 AApplication SpecificsProtection of variable speed drive or soft startsoft stop unit

Environmental

Operate Time35 ms opening with LUB12 for control circuit35 ms opening with LUB32 for control circuit50 ms closing with LUB12 for control circuit50 ms closing with LUB32 for control circuit60 ms closing with LUB12 for control circuit60 ms closing with LUB32 for control circuit70 ms closing with LUB12 for control circuit70 ms closing with LUB32 for control circuitShock Resistance10 gn power poles open conforming to IEC 60068-2-2715 gn power poles closed conforming to IEC 60068-2-27
Storage Interface-40...85 °CIngress ProtectionIP20 front panel and wired terminals conforming to IEC 60947-1IP20 other faces conforming to IEC 60947-1IP40 front panel outside connection zone conforming to IEC 60947-1
Operating Pressure2000 mProtective TreatmentTH conforming to IEC 60068
Vibration Resistance2 gn 5...300 Hz power poles open conforming to IEC 60068-2-64 gn 5...300 Hz power poles closed conforming to IEC 60068-2-6Operating Temperature-25...60 °C with LUCM-25...70 °C with LUCA, LUCB, LUCC, LUCD
Thermal Resistance @ Natural0.35...1.4 A