ONEIC.US
LUCD12BL

点击放大查看

LUCD12BL

Manufacturer
Description
3-phase motor control unit,24Vdc Controllers ADV CNTRL UNIT CL20 3PH 3-12A 24VDC 施耐德(SCHNEIDER) 接触器附件 Schneider Electric component LUCD12BL: advanced control unit LUCD - class 20 - 3...12 A - 24 V DC
Category
对参数有疑问?问 AI 助手

Business

Lead Time14 DaysSubcategorySolid State Relay

Compliance

RoHSCompliantStandardsCSA C22-2 No 14 type EEN 60947-6-2IEC 60947-6-2UL 508 type E with phase barrier
CertificationABSASEFAATEXBVCCCCSADNVGLGOSTLROS (Lloyds register of shipping)ULFault ProtectionClass 20 - frequency limit: 40...60 Hz - temperature compensation: -25...70 °C - conforming to IEC 60947-6-2Class 20 - frequency limit: 40...60 Hz - temperature compensation: -25...70 °C - conforming to UL 508

Electrical

Circuit400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1Load Type3-phase motor - cooling: self-cooled
Trip Range14.2 x Ir +/- 20 %Power - Rated9 kW
Voltage - I/O70 % 500 ms conforming to IEC 61000-4-11Power - Output9 kW at 690 V AC 50/60 Hz5.5 kW at 400...440 V AC 50/60 Hz5.5 kW at 500 V AC 50/60 Hz
Voltage Rating600 V conforming to CSA 22-2 No 14600 V conforming to UL 508690 V conforming to IEC 60947-1Current - Output130 mA at 24 V DC I maximum while closing with LUB12220 mA at 24 V DC I maximum while closing with LUB3260 mA at 24 V DC I rms sealed with LUB1280 mA at 24 V DC I rms sealed with LUB32
Voltage - Supply20...27 V for DC circuit 24 V in operationPower Dissipation (Max)2 W for control circuit with LUB123 W for control circuit with LUB32
Voltage - Breakdown (V(BR)GSS)6 kV conforming to IEC 60947-6-2Impedance - Unbalanced/Balanced10 V/m 3 conforming to IEC 61000-4-3
Resistance - Wiper (Ohms) (Typ)8 kV level 3 in open air conforming to IEC 61000-4-28 kV level 4 on contact conforming to IEC 61000-4-2ESR (Equivalent Series Resistance)2 kV class 3 serial link conforming to IEC 61000-4-44 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
Common Mode Transient Immunity (Min)3 ms

Mechanical

Weight0.14 kgMounting TypePlug-in
Dielectric Diameter10 V conforming to IEC 61000-4-6

Product Info

TypeAdvanced Control UnitUsageAC-41AC-43AC-44
FunctionEarth fault protectionManual resetProtection against overload and short-circuitProtection against phase failure and phase imbalanceProduct TypeAdvanced control unit
CompatibilityASILUFC5ASILUFC51LUFC00LUFDA01LUFDA10LUFDH11LUFN..LUFV2LUFW10LULC031LULC033LULC07LULC08LULC09LULC15Measuring RangeTeSys U
Industry Aliases785901269601, LUCD12BLDevice Short NameLUCD
Control/Display Type24 V dcOther Specifications3 → 12 A
Application SpecificsBasic protection and advanced functions, communication

Environmental

Operate Time35 ms opening with LUB12 for control circuit35 ms opening with LUB32 for control circuit70 ms closing with LUB12 for control circuit70 ms closing with LUB32 for control circuitShock Resistance10 gn power poles open conforming to IEC 60068-2-2715 gn power poles closed conforming to IEC 60068-2-27
Storage Interface-40...85 °CIngress ProtectionIP20 front panel and wired terminals conforming to IEC 60947-1IP20 other faces conforming to IEC 60947-1IP40 front panel outside connection zone conforming to IEC 60947-1
Operating Pressure2000 mProtective TreatmentTH conforming to IEC 60068
Vibration Resistance2 gn 5...300 Hz power poles open conforming to IEC 60068-2-64 gn 5...300 Hz power poles closed conforming to IEC 60068-2-6Operating Temperature-25...60 °C with LUCM-25...70 °C with LUCA, LUCB, LUCC, LUCD
Thermal Resistance @ Natural3...12 A