点击放大查看
LUCC18B
| Manufacturer | |
| Description | Controllers ADV CNTRL UNIT CL10 1PH 4.5-18A 24V Schneider Electric component LUCC18B: advanced control unit LUCC - class 10 - 4.5...18 A - 24 V AC |
| Category |
对参数有疑问?问 AI 助手
Business
| Lead Time | 14 Days | Subcategory | Solid State Relay |
Compliance
| Standards | CSA C22-2 No 14 type EEN 60947-6-2IEC 60947-6-2UL 508 type E with phase barrier | Certification | ABSASEFAATEXBVCCCCSADNVGLGOSTLROS (Lloyds register of shipping)UL |
| Fault Protection | Class 10 - frequency limit: 40...60 Hz - temperature compensation: -25...55 °C - conforming to IEC 60947-6-2Class 10 - frequency limit: 40...60 Hz - temperature compensation: -25...55 °C - conforming to UL 508 | ||
Electrical
| Circuit | 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 | Load Type | Single-phase motor |
| Trip Range | 14.2 x Ir +/- 20 % | Voltage - I/O | 70 % 500 ms conforming to IEC 61000-4-11 |
| Power - Output | 4 kW at 400...440 V AC 50/60 Hz | Voltage Rating | 600 V conforming to CSA 22-2 No 14600 V conforming to UL 508690 V conforming to IEC 60947-1 |
| Current - Output | 140 mA at 24 V AC I maximum while closing with LUB12220 mA at 24 V AC I maximum while closing with LUB3270 mA at 24 V AC I rms sealed with LUB1290 mA at 24 V AC I rms sealed with LUB32 | Voltage - Supply | 20...26.5 V for AC circuit 24 V in operation |
| Power Dissipation (Max) | 3 W for control circuit with LUB32 | Voltage - Breakdown (V(BR)GSS) | 6 kV conforming to IEC 60947-6-2 |
| Impedance - Unbalanced/Balanced | 10 V/m 3 conforming to IEC 61000-4-3 | Resistance - Wiper (Ohms) (Typ) | 8 kV level 3 in open air conforming to IEC 61000-4-28 kV level 4 on contact conforming to IEC 61000-4-2 |
| ESR (Equivalent Series Resistance) | 2 kV class 3 serial link conforming to IEC 61000-4-44 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4 | Common Mode Transient Immunity (Min) | 3 ms |
Mechanical
| Weight | 0.14 kg | Mounting Type | Plug-in |
| Dielectric Diameter | 10 V conforming to IEC 61000-4-6 | ||
Product Info
| Usage | AC-41AC-43AC-44 | Function | Earth fault protectionManual resetProtection against overload and short-circuitProtection against phase failure and phase imbalance |
| Product Type | Advanced control unit | Compatibility | ASILUFC5ASILUFC51LUFC00LUFDA01LUFDA10LUFDH11LUFN..LUFV2LUFW10LULC031LULC033LULC07LULC08LULC09LULC15 |
| Measuring Range | TeSys U | Industry Aliases | 785901222736, LUCC18B |
| Device Short Name | LUCC | Other Specifications | 650 °C conforming to IEC 60695-2-12960 °C parts supporting live components conforming to IEC 60695-2-12 |
| Application Specifics | Basic protection and advanced functions, communication | ||
Environmental
| Operate Time | 35 ms opening with LUB12 for control circuit35 ms opening with LUB32 for control circuit70 ms closing with LUB12 for control circuit70 ms closing with LUB32 for control circuit | Shock Resistance | 10 gn power poles open conforming to IEC 60068-2-2715 gn power poles closed conforming to IEC 60068-2-27 |
| Storage Interface | -40...85 °C | Ingress Protection | IP20 front panel and wired terminals conforming to IEC 60947-1IP20 other faces conforming to IEC 60947-1IP40 front panel outside connection zone conforming to IEC 60947-1 |
| Operating Pressure | 2000 m | Protective Treatment | TH conforming to IEC 60068 |
| Vibration Resistance | 2 gn 5...300 Hz power poles open conforming to IEC 60068-2-64 gn 5...300 Hz power poles closed conforming to IEC 60068-2-6 | Operating Temperature | -25...60 °C with LUCM-25...70 °C with LUCA, LUCB, LUCC, LUCD |
| Thermal Resistance @ Natural | 4.5...18 A | ||