
点击放大查看
LUCA1XES
| Manufacturer | |
| Description | Controllers STD CNTRL UNIT CL10 3PH .3-1.4A 48-72V Schneider Electric component LUCA1XES: standard control unit LUCA - class 10 - 0.35...1.4 A - 48...72 V DC/AC Schneider Electric LUC 系列 0.25 kW 3P DOL 启动器, 440 V 交流, 3相, IP40 |
| Category |
对参数有疑问?问 AI 助手
Business
| Lead Time | 14 Days | Subcategory | Solid State Relay |
Compliance
| Standards | CSA C22-2 No 14 type EEN 60947-6-2IEC 60947-6-2UL 508 type E with phase barrier | Certification | ABSASEFAATEXBVCCCCSADNVGLGOSTLROS (Lloyds register of shipping)UL |
| Fault Protection | Class 10 - frequency limit: 40...60 Hz - temperature compensation: -25...70 °C - conforming to IEC 60947-6-2Class 10 - frequency limit: 40...60 Hz - temperature compensation: -25...70 °C - conforming to UL 508 | ||
Electrical
| Circuit | 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 | Load Type | 3-phase motor - cooling: self-cooled |
| Trip Range | 14.2 x Ir +/- 20 % | Power - Rated | 0.25 kW |
| Voltage - I/O | 70 % 500 ms conforming to IEC 61000-4-11 | Power - Output | 0.25 kW at 400...440 V AC 50/60 Hz |
| Voltage Rating | 600 V conforming to CSA 22-2 No 14600 V conforming to UL 508690 V conforming to IEC 60947-1 | Number of Poles | 3P |
| Current - Output | 280 mA at 48 V AC I maximum while closing with LUB12280 mA at 48 V AC I maximum while closing with LUB32280 mA at 48...72 V DC I maximum while closing with LUB12280 mA at 48...72 V DC I maximum while closing with LUB3235 mA at 48 V AC I rms sealed with LUB1235 mA at 48...72 V DC I rms sealed with LUB1245 mA at 48 V AC I rms sealed with LUB3245 mA at 48...72 V DC I rms sealed with LUB32 | Voltage - Supply | 38.5...72 V for AC circuit 48 V in operation38.5...93 V for DC circuit 48...72 V in operation |
| Frequency - Output 1 | 3 | Power Dissipation (Max) | 2 W for control circuit with LUB123 W for control circuit with LUB32 |
| Voltage - Breakdown (V(BR)GSS) | 6 kV conforming to IEC 60947-6-2 | Impedance - Unbalanced/Balanced | 10 V/m 3 conforming to IEC 61000-4-3 |
| Resistance - Wiper (Ohms) (Typ) | 8 kV level 3 in open air conforming to IEC 61000-4-28 kV level 4 on contact conforming to IEC 61000-4-2 | ESR (Equivalent Series Resistance) | 2 kV class 3 serial link conforming to IEC 61000-4-44 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4 |
| Common Mode Transient Immunity (Min) | 3 ms | ||
Mechanical
| Weight | 0.135 kg | Motor Type | DOL |
| Mounting Type | Plug-in | Dielectric Diameter | 10 V conforming to IEC 61000-4-6 |
Product Info
| Usage | AC-41AC-43AC-44 | Series | LUC |
| Function | Earth fault protectionManual resetProtection against overload and short-circuitProtection against phase failure and phase imbalance | Product Type | Standard control unit |
| Compatibility | ASILUFC5ASILUFC51LUFC00LUFN..LULC031LULC033LULC07LULC08LULC09LULC15 | Measuring Range | TeSys U |
| Industry Aliases | 785901701859, LUCA1XES | Device Short Name | LUCA |
| Other Specifications | 650 °C conforming to IEC 60695-2-12960 °C parts supporting live components conforming to IEC 60695-2-12 | Application Specifics | Basic protection requirements for motor starters: overload and short-circuit |
Environmental
| Operate Time | 35 ms opening with LUB12 for control circuit35 ms opening with LUB32 for control circuit60 ms closing with LUB12 for control circuit60 ms closing with LUB32 for control circuit | Shock Resistance | 10 gn power poles open conforming to IEC 60068-2-2715 gn power poles closed conforming to IEC 60068-2-27 |
| Storage Interface | -40...85 °C | Ingress Protection | IP20 front panel and wired terminals conforming to IEC 60947-1IP20 other faces conforming to IEC 60947-1IP40 front panel outside connection zone conforming to IEC 60947-1 |
| Operating Pressure | 2000 m | Protective Treatment | TH conforming to IEC 60068 |
| Vibration Resistance | 2 gn 5...300 Hz power poles open conforming to IEC 60068-2-64 gn 5...300 Hz power poles closed conforming to IEC 60068-2-6 | Operating Temperature | -25...60 °C with LUCM-25...70 °C with LUCA, LUCB, LUCC, LUCD |
| Thermal Resistance @ Natural | 0.35...1.4 A | ||

