ONEIC.US
LUCA05B

点击放大查看

LUCA05B

Manufacturer
Description
Controllers STD CNTRL UNIT CL10 3PH 1.25-5A 24V 施耐德(SCHNEIDER) 电动机断路器 Schneider Electric component LUCA05B: standard control unit LUCA - class 10 - 1.25...5 A - 24 V AC Schneider Electric LUC 系列 3 千瓦 3P DOL 启动器, 690 V 交流, 3相, IP40
Category
对参数有疑问?问 AI 助手

Business

Lead Time14 DaysSubcategorySolid State Relay

Compliance

StandardsCSA C22-2 No 14 type EEN 60947-6-2IEC 60947-6-2UL 508 type E with phase barrierCertificationABSASEFAATEXBVCCCCSADNVGLGOSTLROS (Lloyds register of shipping)UL
Fault ProtectionClass 10 - frequency limit: 40...60 Hz - temperature compensation: -25...70 °C - conforming to IEC 60947-6-2Class 10 - frequency limit: 40...60 Hz - temperature compensation: -25...70 °C - conforming to UL 508

Electrical

Circuit400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1Load Type3-phase motor - cooling: self-cooled
Trip Range14.2 x Ir +/- 20 %Power - Rated3 千瓦
Voltage - I/O70 % 500 ms conforming to IEC 61000-4-11Power - Output3 kW at 690 V AC 50/60 Hz1.5 kW at 400...440 V AC 50/60 Hz2.2 kW at 500 V AC 50/60 Hz
Voltage Rating600 V conforming to CSA 22-2 No 14600 V conforming to UL 508690 V conforming to IEC 60947-1Number of Poles3P
Current - Output140 mA at 24 V AC I maximum while closing with LUB12220 mA at 24 V AC I maximum while closing with LUB3270 mA at 24 V AC I rms sealed with LUB1290 mA at 24 V AC I rms sealed with LUB32Voltage - Supply20...26.5 V for AC circuit 24 V in operation
Frequency - Output 13Power Dissipation (Max)2 W for control circuit with LUB123 W for control circuit with LUB32
Voltage - Breakdown (V(BR)GSS)6 kV conforming to IEC 60947-6-2Impedance - Unbalanced/Balanced10 V/m 3 conforming to IEC 61000-4-3
Resistance - Wiper (Ohms) (Typ)8 kV level 3 in open air conforming to IEC 61000-4-28 kV level 4 on contact conforming to IEC 61000-4-2ESR (Equivalent Series Resistance)2 kV class 3 serial link conforming to IEC 61000-4-44 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
Common Mode Transient Immunity (Min)3 ms

Mechanical

Weight0.135 kgMotor TypeDOL
Mounting TypePlug-inDielectric Diameter10 V conforming to IEC 61000-4-6

Product Info

UsageAC-41AC-43AC-44SeriesLUC
FunctionEarth fault protectionManual resetProtection against overload and short-circuitProtection against phase failure and phase imbalanceProduct TypeStandard control unit
CompatibilityASILUFC5ASILUFC51LUFC00LUFN..LULC031LULC033LULC07LULC08LULC09LULC15Measuring RangeTeSys U
Industry Aliases785901221869, LUCA05BDevice Short NameLUCA
Other Specifications650 °C conforming to IEC 60695-2-12960 °C parts supporting live components conforming to IEC 60695-2-12Application SpecificsBasic protection requirements for motor starters: overload and short-circuit

Environmental

Operate Time35 ms opening with LUB12 for control circuit35 ms opening with LUB32 for control circuit70 ms closing with LUB12 for control circuit70 ms closing with LUB32 for control circuitShock Resistance10 gn power poles open conforming to IEC 60068-2-2715 gn power poles closed conforming to IEC 60068-2-27
Storage Interface-40...85 °CIngress ProtectionIP20 front panel and wired terminals conforming to IEC 60947-1IP20 other faces conforming to IEC 60947-1IP40 front panel outside connection zone conforming to IEC 60947-1
Operating Pressure2000 mProtective TreatmentTH conforming to IEC 60068
Vibration Resistance2 gn 5...300 Hz power poles open conforming to IEC 60068-2-64 gn 5...300 Hz power poles closed conforming to IEC 60068-2-6Operating Temperature-25...60 °C with LUCM-25...70 °C with LUCA, LUCB, LUCC, LUCD
Thermal Resistance @ Natural1.25...5 A