ATS22C48Q
| Manufacturer | |
| Description | Softstarter ATS22 480A 400V 施耐德(SCHNEIDER) 软启动柜 Schneider Electric component ATS22C48Q: soft starter-ATS22-control 220V-power 230V(132kW)/400...440V(250kW) Schneider Electric ATS22 系列 480 A 软启动器, IP00, 250 kW, 230 → 440 V |
| Category |
对参数有疑问?问 AI 助手
Compliance
| Standards | EN/IEC 60947-4-2 | Compliance | Conducted and radiated emissions conforming to IEC 60947-4-2 level ADamped oscillating waves conforming to IEC 61000-4-12 level 3Electrostatic discharge conforming to IEC 61000-4-2 level 3Immunity to electrical transients conforming to IEC 61000-4-4 level 4Immunity to radiated radio-electrical interference conforming to IEC 61000-4-3 level 3Voltage/current impulse conforming to IEC 61000-4-5 level 3 |
| Protection | Phase failure on lineThermal protection on motorThermal protection on starter | Certification | CCCCSAC-TickGOSTUL |
Electrical
| Input | 750 Ohm | Noise | 56 dB |
| Output | (R1)relay outputs 230 V running, alarm, trip, stopped, not stopped, starting, ready, C/O(R2)relay outputs 230 V running, alarm, trip, stopped, not stopped, starting, ready, C/O | Circuit | 20 W |
| Data Rate | 4800, 9600 or 19200 bps | Frequency | 45...66 Hz |
| Interface | RS485 multidrop | Power - Rated | 250 kW |
| Power - Output | 132 kW at 230 V250 kW at 400 V250 kW at 440 V | Voltage Rating | 440 V |
| Current - Output | 0.4...1 Icl adjustable | Voltage - Supply | 230 → 440 V |
| Current - Sensing | 437 A | Number of Outputs | 2 |
| Current - Switching | Relay outputs 100 mA at 12 V, DC | Current Rating (Max) | 480 A |
| Frequency - Output 1 | 3 | Voltage - Input (Min) | 24 V (<= 30 V) |
| Power Dissipation (Max) | 218 W for standard applications | Phase Noise Typ (dBc/Hz) | 3 |
| Voltage - Collector Emitter Breakdown (Max) | 220 → 230 V | ||
Mechanical
| Depth | 339.7 mm | Width | 304 mm |
| Height | 455 mm | Weight | 50 kg |
| Start Type | Start with torque control (current limited to 3.5 In) | Connector Type | 1 RJ45 |
| Mounting Style | With heat sink | Depth - Overall | 455mm |
| Width - Overall | 304mm | Length - Overall | 339.7mm |
| Number of Positions | 3 phases | Supplier Device Package | ATS22 |
Product Info
| Usage | AC-53A | Series | ATS22 |
| Function | Internal bypass | Protocol | Modbus |
| Label Type | CE | CAD Drawing | 3D CAD Model |
| Product Type | Soft starter | Bus Connection | In the motor supply lineTo the motor delta terminals |
| Communications | Serial | Measuring Range | Altistart 22 |
| Operating Position | Vertical +/- 10 degree | Control/Display Type | 220 → 230 V |
| Other Specifications | (LI1, LI2, LI3)logic 5 mA 4.3 kOhm | Application Specifics | Severe and standard applications |
| RAM Capacity/Installed | 31 | Number of Inputs and Type | 3 |
| For Use With/Related Products | Asynchronous motors | ||
Environmental
| Seal Rating | IP00 | Cooling Type | Forced convection |
| Humidity Range | <= 95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 | Shock Resistance | 15 gn for 11 ms conforming to EN/IEC 60068-2-27 |
| Storage Interface | -25...70 °C | Ingress Protection | Level 2 conforming to IEC 60664-1 |
| Operating Pressure | <= 1000 m without derating> 1000...< 2000 m with current derating of 2.2 % per additional 100 m | Vibration Resistance | 1 gn (f = 13...200 Hz) conforming to EN/IEC 60068-2-61.5 mm (f = 2...13 Hz) conforming to EN/IEC 60068-2-6 |
| Operating Temperature | +40°C | ||