ONEIC.US
TR-61326

点击放大查看

TR-61326

Manufacturer
Description
RELAY;12VAC/DC10ADPDT,PROGRAMMABLE Time Delay Relay Time Ranger Programmable Multi-Range Type:Single Knob Unit Function: Watchdog Input Voltage: 12 VAC/VDC Timing Range: 0.1 sec - 120 min Mounting : Plug-in 11 Pin Round Contact Configuration: DPDT
Category
对参数有疑问?问 AI 助手

Electrical

Load2 VAAccuracy> 2 Seconds Delay +0.1% 0.1 - 2 Seconds Delay +2%
Reset TimeOn Delay/Interval/Repeat Cycle/Delayed Interval: 0.1 Seconds, Off Delay/Single Shot/Watchdog/Triggered Delayed Interval: 0.04 SecondsRange deg/s0.1 sec - 120 min
Voltage Rating12 VAC/VDCCurrent - Output10 Amp
Voltage - SupplyAC Operation: +10/-15% of nominal at 50/60 Hz. DC Operation: +10/-15% of nominal.Contact Voltage (Max)2,000 volts

Mechanical

Mounting Type11 Pin OctalNumber of ContactsDPDT 10A @ 240V AC/28V DC, 1/2HP @ 240V AC, 1/3HP @ 120V AC B300 & R300; AC15 & DC13
Contact Layout, Typical2C DPDTOperating Force - Initial(Time from when power is applied until unit is timing) 120 & 240V units 0.05 Seconds 12, 24 & 48V units 0.08 Seconds

Product Info

TypeSingle Knob UnitFunctionWatchdog
Trigger TypeTiming sequence must be initiated only after input voltage is applied to unit. Minimum required trigger switch closure time is 0.1 seconds.Card StandardSingle Shot
CompatibilityOn all units triggered by input voltage or by a control switch, do not use a solid state switch to initiate the timing sequenceproblems with leakage current could occur. On all units with a power trigger, do not use a solid state switch with leakage curre

Environmental

Temperature12-120V Input Voltage: -28° to 65°C (-18° to 150°F) 240V Input Voltage: -28° to 50°C (-18° to 122°F)Operate Time(Time unit continues to time after power is removed) 0.01 Seconds for all units
Mechanical LifeMechanical: 10,000,000 operations Full Load: 100,000 operations